Technical Details of Ashoka Leyland Generating Set

ENGINEMODELALGPW04D.E4ALGPW04DMK1.E4ALGP6.65.E4ALGPW04CTI.E4ALGP411TC.E4ALGP411TC.E4
POWEROUTPUT (P2)43PSCONT53.2 PS MAX66.5 PS CONT75.5 PS CONT93 PS CONT121 PS CONT
RPM150015001500150015001500
INTAKE SYSTEMNATURALLY
ASPIRATED
NATURALLY
ASPIRATED
NATURALLY
ASPIRATED
NATURALLY
ASPIRATED
NATURALLY
ASPIRATED
NATURALLY
ASPIRATED
RATING STANDARDBS5514BS5514BS5514BS5514BS5514BS5514
ALTERNATOR RATING30405562.575100
FREQUENCY(HZ)505050505050
TYPE OF GOVERNORMECHANICAL
RSV TYPE
MECHANICAL
RSV TYPE
MECHANICAL
RSV TYPE
MECHANICAL
RSV TYPE
MECHANICAL
RSV TYPE
MECHANICAL
RSV TYPE
COOLING SYSTEMWATER
COOLED
WATER
COOLED
WATER
COOLED
WATER
COOLED
WATER
COOLED
WATER
COOLED
INJECTION DIRECTDIRECTDIRECTDIRECTDIRECTDIRECT
CYLINDERS446466
ROTATIONANTI CLOCKWISE VIEWEDFROMFLY WHEEL
BORE(MM)104104107.18104107.18107.18
STROKE(MM)118118120.65113120.65120.65
DISPLACEMENT(L)4.0094.0096.543.8396.546.54
COMPRESSION RATIO17.9:117.9:117.5:117.5:117.25:117.25:1
OVERALL DIMENSION DG SET ( SILENT DG SET DIMENSION )
LENGTH(MM)1700(2953)1700(2953)2120(3400)1755(3100)2120(3500)2520(3500)
WIDTH(MM)1000(1100)1000(1100)950(1550)1000(1400)950(1700)1250(1700)
HEIGHT(MM)1150(2030)1150(2030)1450(2225)1150(2235)1450(2375)1450(2595)
ENGINE REAR END
FLYWHEEL-HOUSINGSAE-3SAE-3SAE-2SAE-3SAE-2SAE-2
FLYWHEELSAE-10SAE-10SAE-11.5SAE-10SAE-11.5SAE-11.5
DRY WEIGHT OF ENGINE(kgs)350350700338730745
LUBRICATING SYSTEM
SUMP OIL CAPACITY(ltr?s)7.57.511.57.511.511.5
OIL SPEC TO BE USED-- APICF4+MB228.1(SAE15W40)
OIL CONSUPTION<0.1% of FC<0.1% of FC<0.15 of FC <0.1% of FC<0.15 of FC <0.15 of FC
FUEL CONSUPTION
SFC LOAD (gm/pshr)123118129117129123
DIESEL SPEC TO BE USED IS 1460
ELECTRIC SYSTEM
SYSTEM VOLTAGE(V)121224122424
STARTER MOTOR TYPEPRE-ENGAGEDPRE-ENGAGEDAXIALPRE-ENGAGEDAXIALAXIAL
--


  • Powering rating as per standard reference condition.
  • SFC is at 75%load with 5% toleranc



    REF.CONDITIONSIS 10002BS 5514
    Temperature27 Deg.C25 Deg.c
    Pressure100KPA (750 mm hg)100 KPA (750 mmhg)
    Humidity60% 30%
    The above specification are liable to change due to continious improvement and are for reference only.




     